QBSERIAL and locked ports

 BBS: Inland Empire Archive
Date: 01-21-93 (22:49)             Number: 304
From: JEFF FREEMAN                 Refer#: NONE
  To: KELLY MUNDELL                 Recvd: NO  
Subj: QBSERIAL and locked ports      Conf: (2) Quik_Bas
Kelly,

    I use QBSerial myself... links nicely with VB/DOS (use
the bc7ser and not qbser).

    But to answer you question:  If the port is locked,
call opencom with the locked port speed.  Use CTS/RTS flow-
control.  If possible, use a fossil (QBSerial 300 supports
Fossils) and you won't have to worry about non-standard
IRQ's and all that.

Hope I helped!

Hasta

---
 * Origin: TheBlackGate,214/519-0080,Home of WarWorld,16.8HST (1:124/7006)